Tripp Lite PDUMV20HVNET2LX 3.7kW Single-Phase 208/230V Switched PDU - LX Platform, 7 C13, 1 C19 Outlets, C20 / L6-20P Inputs, 0U 988mm, TAA

https://images.icecat.biz/img/gallery/39234646_3530595660.jpg
Product code:
GTIN (EAN/UPC):
Data-sheet quality:
created/standardized by Icecat
Product views:
79230
Info modified on:
10 Aug 2024, 11:32:51
Long product name Tripp Lite PDUMV20HVNET2LX 3.7kW Single-Phase 208/230V Switched PDU - LX Platform, 7 C13, 1 C19 Outlets, C20 / L6-20P Inputs, 0U 988mm, TAA:

3.7kW Single-Phase 208/230V Switched PDU - LX Platform, 7 C13, 1 C19 Outlets, C20 / L6-20P Inputs, 0U 988mm, TAA

Tripp Lite PDUMV20HVNET2LX 3.7kW Single-Phase 208/230V Switched PDU - LX Platform, 7 C13, 1 C19 Outlets, C20 / L6-20P Inputs, 0U 988mm, TAA:

The PDUMV20HVNET2LX 3.3-3.7kW Single-Phase Switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. Recommended for your IT or industrial application, it features eight switched outlets (seven C13 and one C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. The C20 inlet is compatible with a wide variety of user-supplied power cords for connecting to an AC source, generator or protected UPS. A detachable 10-ft. (3.05 m) cord with NEMA L6-20P plug is included.

The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2c, SNMPv3, Telnet, SSH, CLI, FTP, DHCP and NTP.

A digital ammeter allows you to monitor the total connected load in real time to ensure it remains well below maximum capacity with no danger of overload. The switched PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.

Distributes, Monitors and Manages Network-Grade AC Power
3.3-3.7kW 208/230 switched PDU with single-phase input
C20 inlet compatible with wide variety of user-supplied power cords
Detachable 10-ft. (3.05 m) cord with NEMA L6-20P plug included
Firmware upgrades support future product enhancements

7 C13 and 1 C19 Switched Outlets Distribute AC Power
Individual outlets can be remotely controlled to power up, power down, reboot or lock out devices
Included plug-lock inserts prevent cables from becoming accidentally disconnected

Digital Ammeter
Reports total connected equipment load in real time
Supports IP-address self-ID
Rotates 180° for easy reading at either angle

Built-In LX Platform Interface
Pre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities
PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
IP-based Auto Probe detects lost connectivity and restores service autonomously

Easy 0U Installation in EIA-Standard 19 in. Racks
Mounts vertically using included toolless buttons or rack-mounting brackets
Included PDUMVROTATEBRKT allows mounting with rear-facing outlets

TAA-Compliant
Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Short summary description Tripp Lite PDUMV20HVNET2LX 3.7kW Single-Phase 208/230V Switched PDU - LX Platform, 7 C13, 1 C19 Outlets, C20 / L6-20P Inputs, 0U 988mm, TAA:

Tripp Lite PDUMV20HVNET2LX 3.7kW Single-Phase 208/230V Switched PDU - LX Platform, 7 C13, 1 C19 Outlets, C20 / L6-20P Inputs, 0U 988mm, TAA, Switched, 0U, Single-phase, Vertical, Black, 8 AC outlet(s)

Long summary description Tripp Lite PDUMV20HVNET2LX 3.7kW Single-Phase 208/230V Switched PDU - LX Platform, 7 C13, 1 C19 Outlets, C20 / L6-20P Inputs, 0U 988mm, TAA:

Tripp Lite PDUMV20HVNET2LX 3.7kW Single-Phase 208/230V Switched PDU - LX Platform, 7 C13, 1 C19 Outlets, C20 / L6-20P Inputs, 0U 988mm, TAA. PDU types: Switched, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 8 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: NEMA L6-20P. Cable length: 3.05 m. Monitoring: Current, Power, Outlet control: Lock-out, Recycle, Turn off, Turn on, Supported network protocols: IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP. Nominal input voltage: 208-230 V, Maximum current: 20 A, AC input frequency: 50 - 60 Hz

Bullet Points Tripp Lite PDUMV20HVNET2LX 3.7kW Single-Phase 208/230V Switched PDU - LX Platform, 7 C13, 1 C19 Outlets, C20 / L6-20P Inputs, 0U 988mm, TAA:
  • - 3.3-3.7kW 208/230 single-phase switched 1-meter 0U PDU
  • - 8 individually controllable outlets—7 C13, 1 C19
  • - Pre-installed WEBCARDLX with latest version of PADM20 for IP-based Auto Probe feature
  • - Digital ammeter for on-site load monitoring in real time
  • - C20 inlet input with detachable 10-ft. (3.05 m) NEMA L6-20P power cord
Warranty:
2-year limited
Embed the product datasheet into your content