Tripp Lite 1.4kW Single-Phase ATS / Switched PDU, 120V (8 5-15R), 2 5-15P, 100-127V Input, 2 12ft Cords, 1U Rack-Mount

  • Brand : Tripp Lite
  • Product name : 1.4kW Single-Phase ATS / Switched PDU, 120V (8 5-15R), 2 5-15P, 100-127V Input, 2 12ft Cords, 1U Rack-Mount
  • Product code : PDUMH15ATNET
  • GTIN (EAN/UPC) : 0037332136428
  • Category : Power Distribution Units (PDUs)
  • Data-sheet quality : created/standardized by Icecat
  • Product views : 109471
  • Info modified on : 19 Feb 2024 22:57:24
  • Warranty: : 2-year limited warranty
  • Long product name Tripp Lite 1.4kW Single-Phase ATS / Switched PDU, 120V (8 5-15R), 2 5-15P, 100-127V Input, 2 12ft Cords, 1U Rack-Mount :

    1.4kW Single-Phase ATS / Switched PDU, 120V (8 5-15R), 2 5-15P, 100-127V Input, 2 12ft Cords, 1U Rack-Mount

  • Tripp Lite 1.4kW Single-Phase ATS / Switched PDU, 120V (8 5-15R), 2 5-15P, 100-127V Input, 2 12ft Cords, 1U Rack-Mount :

    Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.
    - 120V 15A Automatic Transfer Switch (ATS) / Switched PDU (Agency de-rated to 12A continuous)
    - Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord
    - Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface
    - Digital display continuously reports total output power consumption in amps
    - 8 switched NEMA 5-15R outlets
    - 1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth
    - Set of two 12 ft. / 3.6m NEMA 5-15P input cables support connection to separate PRIMARY and SECONDARY power sources
    - ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
    - ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)
    - Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
    - On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
    - Super-fast switchover between primary and secondary power sources occurs in 2-7 milliseconds
    - DHCP/Manual configuration support; Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols
    - Compatible with optional ENVIROSENSE temperature monitor
    - Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first energized
    - Front panel LEDs confirm power availability on both input lines
    - TAA Compliant Version Available - Order Tripp Lite PDUMH15ATNETAA

  • Short summary description Tripp Lite 1.4kW Single-Phase ATS / Switched PDU, 120V (8 5-15R), 2 5-15P, 100-127V Input, 2 12ft Cords, 1U Rack-Mount :

    Tripp Lite 1.4kW Single-Phase ATS / Switched PDU, 120V (8 5-15R), 2 5-15P, 100-127V Input, 2 12ft Cords, 1U Rack-Mount, Switched, 1U, Horizontal, Metal, Black, 8 AC outlet(s)

  • Long summary description Tripp Lite 1.4kW Single-Phase ATS / Switched PDU, 120V (8 5-15R), 2 5-15P, 100-127V Input, 2 12ft Cords, 1U Rack-Mount :

    Tripp Lite 1.4kW Single-Phase ATS / Switched PDU, 120V (8 5-15R), 2 5-15P, 100-127V Input, 2 12ft Cords, 1U Rack-Mount. PDU types: Switched, Rack capacity: 1U, Mounting: Horizontal. AC outlets quantity: 8 AC outlet(s), AC outlet types: NEMA 5–15R, Power plug: NEMA 5–15P. Cable length: 3.66 m, Certification: UL 60950-1, CSA, Class A, NOM. Nominal input voltage: 100-127 V, Maximum current: 15 A, AC input frequency: 60 Hz. Width: 444.5 mm, Depth: 368.3 mm, Dimensions (WxDxH): 444 x 368 x 44.4 mm

Specs
Design
PDU types Switched
Rack capacity 1U
Mounting Horizontal
Housing material Metal
Product colour Black
Ports & interfaces
AC outlets quantity 8 AC outlet(s)
Power plug NEMA 5–15P
AC outlet types NEMA 5–15R
I/O ports 60950 (USA, Canada), Class A, NOM (Mexico), RoHS
Features
Cable length 3.66 m
Certification UL 60950-1, CSA, Class A, NOM
Power
Nominal input voltage 100-127 V
AC input frequency 60 Hz
Maximum current 15 A
Nominal output voltage 100-127 V

Weight & dimensions
Width 444.5 mm
Depth 368.3 mm
Dimensions (WxDxH) 444 x 368 x 44.4 mm
Height 44.4 mm
Weight 4.99 kg
Packaging data
Package weight 7.26 kg
Package width 528.3 mm
Package depth 589.3 mm
Package height 134.6 mm
Operational conditions
Storage temperature (T-T) -15 - 50 °C
Operating altitude 0 - 3000 m
Technical details
Sustainability certificates RoHS
Logistics data
Country of origin Taiwan
Products per master (outer) case 1 pc(s)
Similar products
Product: PDUMH30-ISO
Product code: PDUMH30-ISO
Stock:
Price from: 0(excl. VAT) 0(incl. VAT)
Product: PDUMH20ATS
Product code: PDUMH20ATS
Stock:
Price from: 0(excl. VAT) 0(incl. VAT)
Product code: PDUMH15ATS
Stock:
Price from: 0(excl. VAT) 0(incl. VAT)
Product code: PDUMNH20AT1
Stock:
Price from: 0(excl. VAT) 0(incl. VAT)
Product code: PDUMNH15AT1
Stock:
Price from: 0(excl. VAT) 0(incl. VAT)
Distributors
Country Distributor
2 distributor(s)